Location: Home > Product Center > PV Cable

TUV single insulation photovoltaic storage cable

Conductor: EN60228 Class 5 soft annealed stranded copper

Insulation: Electron -beam cross - linked materials with RoHS compliance

Rated voltage: 600V DC

Test voltage: 600V DC=3000V, 5Min.

Ambient temperature: -40℃ up to +125

Insulation volume resistivity: 1x1011 Ωcm

Low temperature impact test:-40 ± 2*16h, compliance with the EN60811-506 standard

Low temperature bending test: (cable outer diameter ≤ 12.5 mm) -40 2* 16h, in accordance with EN60811-504, without cracking

Shrinkage test: Comply with EN 60811-503, 200℃, 1h, shrinkagc ≦ 2%

Compatibility test: 10 days at 135 ± 2, Tensile strength Median, min. 5.0N/mm², Variation-30%

Elongation at break Median, min. 200%, Variation -30%

Continuous aging in oven: compliance with the EN60811-401 standard, 40 ± 2/240h, Values to beo btained for tensile strength, Variation, max. ± 20%

Values to beobtained for elongation at brek, Variation, max.± 20%

Acid resistance test: lSO 6722-1, 5.17.3 (Indoor)

Smoke density (Suitable for low smoke without halogcn cablc): EN 61034-2, Light transmittance≥ 60%

Halogen content test: EN 50525-1 Annex B

Flame retardance: EN 60332-1-2 (Whole wire) (Indoor)

Artificial climate aging test: TUV accreditation 2 PfG 2693/06.19 Anncx F

Salt spray test (when applicable): EC 60068-2-11 and 2 PfG 2693, Clause8.3.12


Core*Cross section(mm²)Conductor constuction/(N/mm)DC 600V, ESL06Z3-K 125℃ ESW06Z3-K 125
Ave.Thic.(mm)Maximum OD. of finished cable(mm)
4.0

56/0.285

0.50

4.20
6.084/0.2850.50

4.80

10.0

497/0.16

0.60

6.10

160.513/0.200.707.70
25.0798/0.200.709.40
35.01121/0.200.8011.20
50.0
1596/0.200.9013.20
70.02997/0.201.0015.60