Conductor: EN60228 Class 5 soft annealed stranded copper
Insulation: Electron -beam cross - linked materials with RoHS compliance
Rated voltage: 600V DC
Test voltage: 600V DC=3000V, 5Min.
Ambient temperature: -40℃ up to +125℃
Insulation volume resistivity: 1x1011 Ωcm
Low temperature impact test:-40 ± 2℃*16h, compliance with the EN60811-506 standard
Low temperature bending test: (cable outer diameter ≤ 12.5 mm) -40 2℃* 16h, in accordance with EN60811-504, without cracking
Shrinkage test: Comply with EN 60811-503, 200℃, 1h, shrinkagc ≦ 2%
Compatibility test: 10 days at 135 ± 2℃, Tensile strength Median, min. 5.0N/mm², Variation-30%
Elongation at break Median, min. 200%, Variation -30%
Continuous aging in oven: compliance with the EN60811-401 standard, 40 ± 2℃/240h, Values to beo btained for tensile strength, Variation, max. ± 20%
Values to beobtained for elongation at brek, Variation, max.± 20%
Acid resistance test: lSO 6722-1, 5.17.3 (Indoor)
Smoke density (Suitable for low smoke without halogcn cablc): EN 61034-2, Light transmittance≥ 60%
Halogen content test: EN 50525-1 Annex B
Flame retardance: EN 60332-1-2 (Whole wire) (Indoor)
Artificial climate aging test: TUV accreditation 2 PfG 2693/06.19 Anncx F
Salt spray test (when applicable): EC 60068-2-11 and 2 PfG 2693, Clause8.3.12